Search
Search Results (8 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2020-11956 | 1 Rittal | 9 Cmc Iii Pu 7030.000, Cmc Iii Pu 7030.000 Firmware, Cmciii-pu-9333e0fb and 6 more | 2024-11-21 | 9.8 Critical |
| An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a least privilege violation. | ||||
| CVE-2020-11955 | 1 Rittal | 9 Cmc Iii Pu 7030.000, Cmc Iii Pu 7030.000 Firmware, Cmciii-pu-9333e0fb and 6 more | 2024-11-21 | 8.8 High |
| An issue was discovered on Rittal PDU-3C002DEC through 5.15.70 and CMCIII-PU-9333E0FB through 3.15.70 devices. There are insecure permissions. | ||||
| CVE-2020-11953 | 1 Rittal | 9 Cmc Iii Pu 7030.000, Cmc Iii Pu 7030.000 Firmware, Cmciii-pu-9333e0fb and 6 more | 2024-11-21 | 8.8 High |
| An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code. | ||||
| CVE-2020-11952 | 1 Rittal | 9 Cmc Iii Pu 7030.000, Cmc Iii Pu 7030.000 Firmware, Cmciii-pu-9333e0fb and 6 more | 2024-11-21 | 6.2 Medium |
| An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu. | ||||
| CVE-2020-11951 | 1 Rittal | 9 Cmc Iii Pu 7030.000, Cmc Iii Pu 7030.000 Firmware, Cmciii-pu-9333e0fb and 6 more | 2024-11-21 | 9.8 Critical |
| An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account. | ||||
| CVE-2019-19393 | 1 Rittal | 2 Cmc Pu Iii 7030.000, Cmc Pu Iii 7030.000 Firmware | 2024-11-21 | 6.1 Medium |
| The Web application on Rittal CMC PU III 7030.000 V3.00 V3.11.00_2 to V3.15.70_4 devices fails to sanitize user input on the system configurations page. This allows an attacker to backdoor the device with HTML and browser-interpreted content (such as JavaScript or other client-side scripts) as the content is always displayed after and before login. Persistent XSS allows an attacker to modify displayed content or to change the victim's information. Successful exploitation requires access to the web management interface, either with valid credentials or a hijacked session. | ||||
| CVE-2019-13553 | 2 Carel, Rittal | 2 Pcoweb Firmware, Chiller Sk 3232 | 2024-11-21 | 9.8 Critical |
| Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point. | ||||
| CVE-2019-13549 | 2 Carel, Rittal | 2 Pcoweb Firmware, Chiller Sk 3232 | 2024-11-21 | 7.5 High |
| Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication. | ||||
Page 1 of 1.