| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An OS command vulnerability exists in CoreTec product that allows authenticated users with certain roles to execute arbitrary system commands with full control over the device. The vulnerability exists in the configuration daemon's time synchronization handler, which is responsible for setting the system time-zone. When processing time-zone configuration updates, the daemon constructs a shell command by concatenating user-supplied input without any sanitization or validation. |
| The embedded web server on ABB Fox515T 1.0 devices is vulnerable to Local File Inclusion. It accepts a parameter that specifies a file for display or for use as a template. The filename is not validated; an attacker could retrieve any file. |
| An Unprotected Transport of Credentials issue was discovered in ABB Ellipse 8.3 through Ellipse 8.9 released prior to December 2017 (including Ellipse Select). A vulnerability exists in the authentication of Ellipse to LDAP/AD using the LDAP protocol. An attacker could exploit the vulnerability by sniffing local network traffic, allowing the discovery of authentication credentials. |
| An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. An improper input validation vulnerability has been identified, allowing a local attacker to provide a malicious parameter to the script that is not validated by the application, This could enable the attacker to retrieve any file on the server. |
| An attacker could exploit this vulnerability in Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 by tricking a user to click on a link containing malicious code that would then be run by the web browser. This can result in the compromise of confidential information, or even the takeover of the user’s session. |
| An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials. |
|
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
|
|
The affected products store both public and private key that are used to sign and
protect Custom Parameter Set (CPS) file from modification. An attacker that manages to exploit this vulnerability will be able to change
the CPS file, sign it so that it is trusted as the legitimate CPS file.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
|
|
Communication between the client and the server application of the affected products is partially done using CORBA (Common Object Request Broker Architecture) over TCP/IP. This protocol is not encrypted and allows tracing of internal messages.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
|
| Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* |
| Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions. |
| Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0; 1.3.0.1; 1.2.0. Hitachi Energy PWC600 1.0.1 version 1.0.1.4 and prior versions; 1.1.0 version 1.1.0.1 and prior versions. |
| Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions). |
| A vulnerability exists in the file upload validation part of Hitachi Energy TXpert Hub CoreTec 4 product. The vulnerability allows an attacker or malicious agent who manages to gain access to the system and obtain an account with sufficient privilege to upload a malicious firmware to the product. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0; 2.0.1; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1. |
| Improper Input Validation vulnerability in a particular configuration setting field of Hitachi Energy TXpert Hub CoreTec 4 product, allows an attacker with access to an authorized user with ADMIN or ENGINEER role rights to inject an OS command that is executed by the system. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0; 2.0.1; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1. |
| A vulnerability in the application authentication and authorization mechanism in Hitachi Energy's TXpert Hub CoreTec 4, that depends on a token validation of the session identifier, allows an unauthorized modified message to be executed in the server enabling an unauthorized actor to change an existing user password, and further gain authorized access into the system via login mechanism. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0 2.1.0; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1. |
| Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing (CSB) allows an attacker or unauthorized user to access database credentials, shut down the product and access or alter. This issue affects: Hitachi ABB Power Grids Retail Operations version 5.7.2 and prior versions. Hitachi ABB Power Grids Counterparty Settlement Billing (CSB) version 5.7.2 and prior versions. |
| Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute a modified signed Java Applet JAR file. A successful exploitation may lead to data extraction or modification of data inside the application. This issue affects: Hitachi Energy Retail Operations 5.7.3 and prior versions. Hitachi Energy Counterparty Settlement and Billing (CSB) 5.7.3 prior versions. |
| Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions. |
| Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager – SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager – SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257). |