CVE Vendors Products Updated CVSS v3.1
CVE-2025-53947 2 Cognex, Microsoft 3 In-sight Camera Firmware, In-sight Explorer, Windows 2026-04-15 7.7 High
A local attacker with low privileges on the Windows system where the software is installed can exploit this vulnerability to corrupt sensitive data. A data folder is created with very weak privileges, allowing any user logged into the Windows system to modify its content.
CVE-2025-53969 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2026-04-15 8.8 High
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a service implementing a proprietary protocol on TCP port 1069 to allow the client-side software, such as the In-Sight Explorer tool, to perform management operations such as changing network settings or modifying users' access to the device.
CVE-2021-32935 1 Cognex 1 In-sight Opc Server 2025-04-16 8.8 High
The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation.