Search Results (38 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-20234 2 Belden, Garrettcom 2 Garrettcom Magnum 6k And 10k Managed Switches, Magnum Managed Networks Software-6k 2026-10-01 9.8 Critical
GarrettCom Magnum 6K and 10K managed switches contain an authentication bypass vulnerability that allows unauthenticated attackers to gain unauthorized access by exploiting a hardcoded string in the authentication mechanism. Attackers can bypass login controls to access administrative functions and sensitive switch configuration without valid credentials.
CVE-2018-25237 1 Belden 2 Hirschmann Eagle One, Hirschmann Hisecos 2026-10-01 9.8 Critical
Hirschmann HiSecOS devices versions prior to 05.3.03 contain a buffer overflow vulnerability in the HTTPS login interface when RADIUS authentication is enabled that allows remote attackers to crash the device or execute arbitrary code by submitting a password longer than 128 characters. Attackers can exploit improper bounds checking in password handling to overflow a fixed-size buffer and achieve denial of service or remote code execution.
CVE-2020-37216 1 Belden 1 Hirschmann Hios 2026-07-15 7.5 High
Hirschmann HiOS devices versions prior to 08.1.00 and 07.1.01 contain a denial of service vulnerability in the EtherNet/IP stack where improper handling of packet length fields allows remote attackers to crash or hang the device. Attackers can send specially crafted UDP EtherNet/IP packets with a length value larger than the actual packet size to render the device inoperable.
CVE-2018-25236 1 Belden 2 Hirschmann Hios, Hirschmann Hisecos 2026-07-15 9.8 Critical
Hirschmann HiOS and HiSecOS products RSP, RSPE, RSPS, RSPL, MSP, EES, EESX, GRS, OS, RED, EAGLE contain an authentication bypass vulnerability in the HTTP(S) management module that allows unauthenticated remote attackers to gain administrative access by crafting specially formed HTTP requests. Attackers can exploit improper authentication handling to obtain the authentication status and privileges of a previously authenticated user without providing valid credentials.
CVE-2017-20238 1 Belden 1 Hirschmann Industrial Hivision 2026-05-12 7.1 High
Hirschmann Industrial HiVision versions 06.0.00 and 07.0.00 prior to 06.0.06 and 07.0.01 contains an improper authorization vulnerability that allows read-only users to gain write access to managed devices by bypassing access control mechanisms. Attackers can exploit alternative interfaces such as the web interface or SNMP browser to modify device configurations despite having restricted permissions.
CVE-2017-20233 1 Belden 4 Hirschmann Hilcos Bat450, Hirschmann Hilcos Bat867, Hirschmann Hilcos Openbat and 1 more 2026-05-12 5.4 Medium
Hirschmann HiLCOS products OpenBAT, BAT450, WLC, BAT867 contains a firewall filtering vulnerability that fails to correctly filter IPv4 multicast and broadcast traffic when management IP address filtering is disabled, allowing configured filter rules to be bypassed. Attackers with network access can inject or observe multicast and broadcast packets that should have been blocked by the firewall.
CVE-2016-15058 1 Belden 1 Hirschmann Hilcos Classic Platform 2026-05-12 8.1 High
Hirschmann HiLCOS Classic Platform switches Classic L2E, L2P, L3E, L3P versions prior to 09.0.06 and Classic L2B prior to 05.3.07 contain a credential exposure vulnerability where user passwords are synchronized with SNMPv1/v2 community strings and transmitted in plaintext when the feature is enabled. Attackers with local network access can sniff SNMP traffic or extract configuration data to recover plaintext credentials and gain unauthorized administrative access to the switches.
CVE-2015-10148 1 Belden 1 Hirschmann Hilcos 2026-05-12 8.2 High
Hirschmann HiLCOS devices OpenBAT, WLC, BAT300, BAT54 prior to 8.80 and OpenBAT prior to 9.10 are shipped with identical default SSH and SSL keys that cannot be changed, allowing unauthenticated remote attackers to decrypt or intercept encrypted management communications. Attackers can perform man-in-the-middle attacks, impersonate devices, and expose sensitive information by leveraging the shared default cryptographic keys across multiple devices.
CVE-2017-20237 1 Belden 1 Hirschmann Industrial Hivision 2026-04-07 9.8 Critical
Hirschmann Industrial HiVision versions prior to 06.0.07 and 07.0.03 contains an authentication bypass vulnerability in the master service that allows unauthenticated remote attackers to execute arbitrary commands with administrative privileges. Attackers can invoke exposed interface methods over the remote service to bypass authentication and achieve remote code execution on the underlying operating system.
CVE-2017-11401 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2025-04-20 N/A
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Improper handling of the mbap.length field of ModBus packets in the ModBus DPI filter allows an attacker to send malformed/crafted packets to a protected asset, bypassing function code filtering.
CVE-2017-11402 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2025-04-20 N/A
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift.
CVE-2017-11400 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2025-04-20 N/A
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned.
CVE-2016-2509 1 Belden 6 Hirschmann Firmware, Hirschmann L2b, Hirschmann L2e and 3 more 2025-04-12 N/A
The password-sync feature on Belden Hirschmann Classic Platform switches L2B before 05.3.07 and L2E, L2P, L3E, and L3P before 09.0.06 sets an SNMP community to the same string as the administrator password, which allows remote attackers to obtain sensitive information by sniffing the network.
CVE-2021-30066 2 Belden, Schneider-electric 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more 2024-11-21 6.8 Medium
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.
CVE-2021-30065 2 Belden, Schneider-electric 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more 2024-11-21 7.5 High
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.
CVE-2021-30064 2 Belden, Schneider-electric 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more 2024-11-21 9.8 Critical
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
CVE-2021-30063 2 Belden, Schneider-electric 22 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 19 more 2024-11-21 7.5 High
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.
CVE-2021-30062 2 Belden, Schneider-electric 22 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 19 more 2024-11-21 7.5 High
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer.
CVE-2021-30061 2 Belden, Schneider-electric 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more 2024-11-21 6.8 Medium
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.
CVE-2021-27734 1 Belden 2 Hirschmann Hios, Hisecos 2024-11-21 9.8 Critical
Hirschmann HiOS 07.1.01, 07.1.02, and 08.1.00 through 08.5.xx and HiSecOS 03.3.00 through 03.5.01 allow remote attackers to change the credentials of existing users.