| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Reolink Desktop Application 8.18.12 contains hardcoded credentials as the Initialization Vector (IV) in its AES-CFB encryption implementation allowing attackers with access to the application environment to reliably decrypt encrypted configuration data. NOTE: the Supplier's position is that material is not hardcoded and is instead randomly generated on each installation of the application. |
| GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network. |
| RUCKUS Network Director (RND) before 4.5 allows spoofing of an administrator JWT by an attacker who knows the hardcoded value of a certain secret key. |
| Hospira MedNet before 6.1 uses hardcoded cryptographic keys for protection of data transmission from infusion pumps, which allows remote attackers to obtain sensitive information by sniffing the network. |
| The Flock Safety DetectionProcessing com.flocksafety.android.objects application 6.35.33 for Android (installed on Falcon and Sparrow License Plate Readers and Bravo Edge AI Compute Devices) bundles a Java Keystore (flock_rye.bks) along with its hardcoded password (flockhibiki17) in its code. The keystore contains a private key. |
| ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic AES encryption key, which can be easily derived. |
| ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic WPA2-PSK, which can be easily derived. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. |
| A Use of Hard-coded Cryptographic Key issue was discovered in Korenix JetNet JetNet5018G version 1.4, JetNet5310G version 1.4a, JetNet5428G-2G-2FX version 1.4, JetNet5628G-R version 1.4, JetNet5628G version 1.4, JetNet5728G-24P version 1.4, JetNet5828G version 1.1d, JetNet6710G-HVDC version 1.1e, and JetNet6710G version 1.1. An attacker may gain access to hard-coded certificates and private keys allowing the attacker to perform man-in-the-middle attacks. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| lib/util/miq-password.rb in Red Hat CloudForms 3.0 Management Engine (CFME) before 5.2.4.2 uses a hard-coded salt, which makes it easier for remote attackers to guess passwords via a brute force attack. |
| Nexpose and InsightVM virtual appliances downloaded between April 5th, 2017 and May 3rd, 2017 contain identical SSH host keys. Normally, a unique SSH host key should be generated the first time a virtual appliance boots. |
| Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users’ credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document. |
| ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products utilize an encryption key in the data exchange process, which is hardcoded. This could allow an attacker to gain access to sensitive information. |
| A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server. |
| A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection. |
| Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet. |
| The use of multiple hard-coded cryptographic keys in cSRX Series software in Juniper Networks Junos OS allows an attacker to take control of any instance of a cSRX deployment through device management services. This issue affects: Juniper Networks Junos OS on cSRX Series: All versions prior to 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2. |