Search Results (94 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2012-3021 1 Ge 1 Intelligent Platforms Proficy Real-time Information Portal 2025-04-11 N/A
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.
CVE-2012-3010 1 Ge 1 Intelligent Platforms Proficy Real-time Information Portal 2025-04-11 N/A
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3021 and CVE-2012-3026.
CVE-2012-2516 1 Ge 5 Intelligent Platforms Proficy Batch Execution, Intelligent Platforms Proficy Historian, Intelligent Platforms Proficy Hmi\/scada Ifix and 2 more 2025-04-11 N/A
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a "command injection vulnerability."
CVE-2012-2515 2 Emc, Ge 7 Captiva Quickscan Pro, Documentum Applicationxtender Desktop, Intelligent Platforms Proficy Batch Execution and 4 more 2025-04-11 N/A
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.
CVE-2012-0232 1 Ge 1 Intelligent Platforms Proficy Real-time Information Portal 2025-04-11 N/A
Directory traversal vulnerability in rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6, 3.0, 3.0 SP1, and 3.5 allows remote attackers to modify the configuration via crafted strings.
CVE-2012-0231 1 Ge 1 Intelligent Platforms Proficy Plant Applications 2025-04-11 N/A
PRLicenseMgr.exe in the Proficy Server License Manager in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12401.
CVE-2012-0230 1 Ge 1 Intelligent Platforms Proficy Plant Applications 2025-04-11 N/A
PRRDS.exe in the Proficy Remote Data Service in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12299.
CVE-2012-0229 1 Ge 1 Intelligent Platforms Proficy Historian 2025-04-11 N/A
The Data Archiver service in GE Intelligent Platforms Proficy Historian 4.5 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted session on TCP port 14000 to (1) ihDataArchiver.exe or (2) ihDataArchiver_x64.exe.
CVE-2011-3320 1 Ge 1 Intelligent Platforms Proficy Historian 2025-04-11 N/A
Cross-site scripting (XSS) vulnerability in the Web Administrator component in GE Intelligent Platforms Proficy Historian 4.x and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified parameters.
CVE-2011-1919 1 Ge 1 Intelligent Platforms Proficy Historian 2025-04-11 N/A
Multiple stack-based buffer overflows in GE Intelligent Platforms Proficy Applications before 4.4.1 SIM 101 and 5.x before 5.0 SIM 43 allow remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via crafted TCP message traffic to (1) PRProficyMgr.exe in Proficy Server Manager, (2) PRGateway.exe in Proficy Server Gateway, (3) PRRDS.exe in Proficy Remote Data Service, or (4) PRLicenseMgr.exe in Proficy Server License Manager.
CVE-2011-1918 1 Ge 1 Intelligent Platforms Proficy Historian 2025-04-11 N/A
Stack-based buffer overflow in the Data Archiver service in GE Intelligent Platforms Proficy Historian before 3.5 SIM 17 and 4.x before 4.0 SIM 12 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via crafted TCP message traffic.
CVE-2021-31477 1 Ge 2 Reason Rpv311 Firmware, Rpv311 2024-11-21 7.3 High
This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852.
CVE-2021-27454 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2024-11-21 7.8 High
The software performs an operation at a privilege level higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2021-27452 1 Ge 2 Mu320e, Mu320e Firmware 2024-11-21 7.8 High
The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1).
CVE-2021-27450 1 Ge 2 Mu320e, Mu320e Firmware 2024-11-21 7.8 High
SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1).
CVE-2021-27448 1 Ge 2 Mu320e, Mu320e Firmware 2024-11-21 7.8 High
A miscommunication in the file system allows adversaries with access to the MU320E to escalate privileges on the MU320E (all firmware versions prior to v04A00.1).
CVE-2021-27440 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2024-11-21 9.8 Critical
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2021-27438 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2024-11-21 8.8 High
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2020-6992 1 Ge 1 Cimplicity 2024-11-21 6.7 Medium
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.
CVE-2020-6977 1 Ge 32 Invenia Abus Scan Station, Invenia Abus Scan Station Firmware, Logiq E10 and 29 more 2024-11-21 6.8 Medium
A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5