Search
Search Results (7 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2014-2343 | 1 Trianglemicroworks | 1 Scada Data Gateway | 2025-10-02 | N/A |
| Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line. | ||||
| CVE-2014-2342 | 1 Trianglemicroworks | 1 Scada Data Gateway | 2025-10-02 | N/A |
| Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet. | ||||
| CVE-2013-2794 | 1 Trianglemicroworks | 3 .net Communication Protocol Components, Ansi C Source Code Libraries, Scada Data Gateway | 2025-04-11 | N/A |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. | ||||
| CVE-2013-2793 | 1 Trianglemicroworks | 3 .net Communication Protocol Components, Ansi C Source Code Libraries, Scada Data Gateway | 2025-04-11 | N/A |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. | ||||
| CVE-2020-10615 | 1 Trianglemicroworks | 1 Scada Data Gateway | 2024-11-21 | 7.5 High |
| Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability. | ||||
| CVE-2020-10613 | 1 Trianglemicroworks | 1 Scada Data Gateway | 2024-11-21 | 7.5 High |
| Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets. | ||||
| CVE-2020-10611 | 1 Trianglemicroworks | 1 Scada Data Gateway | 2024-11-21 | 9.8 Critical |
| Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets. | ||||
Page 1 of 1.