Search Results (286 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2010-2772 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2025-04-11 7.8 High
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
CVE-2012-3032 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 N/A
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.
CVE-2012-3031 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 N/A
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.
CVE-2012-3030 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 N/A
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
CVE-2012-3028 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 N/A
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
CVE-2012-3017 1 Siemens 4 Simatic S7-400 Cpu 414-3 Pn\/dp, Simatic S7-400 Cpu 416-3 Pn\/dp, Simatic S7-400 Cpu 416f-3 Pn\/dp and 1 more 2025-04-11 N/A
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.
CVE-2012-3016 1 Siemens 6 Simatic S7-400 Cpu 412-2 Pn, Simatic S7-400 Cpu 414-3 Pn\/dp, Simatic S7-400 Cpu 414f-3 Pn\/dp and 3 more 2025-04-11 N/A
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.
CVE-2020-8745 2 Intel, Siemens 43 Converged Security And Manageability Engine, Trusted Execution Technology, Simatic Drive Controller and 40 more 2025-03-28 6.8 Medium
Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.
CVE-2019-10923 1 Siemens 78 Cp1604, Cp1604 Firmware, Cp1616 and 75 more 2025-02-11 7.5 High
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
CVE-2021-3449 13 Checkpoint, Debian, Fedoraproject and 10 more 172 Multi-domain Management, Multi-domain Management Firmware, Quantum Security Gateway and 169 more 2024-11-21 5.9 Medium
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
CVE-2021-33737 1 Siemens 12 Simatic Cp343-1, Simatic Cp343-1 Advanced, Simatic Cp 343-1 Advanced Firmware and 9 more 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 ERPC (All versions), SIMATIC CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3). Sending a specially crafted packet to port 102/tcp of an affected device could cause a denial of service condition. A restart is needed to restore normal operations.
CVE-2021-33716 1 Siemens 4 Simatic Cp 1543-1, Simatic Cp 1543-1 Firmware, Simatic Cp 1545-1 and 1 more 2024-11-21 6.5 Medium
A vulnerability has been identified in SIMATIC CP 1543-1 (incl. SIPLUS variants) (All versions < V3.0), SIMATIC CP 1545-1 (All versions < V1.1). An attacker with access to the subnet of the affected device could retrieve sensitive information stored in cleartext.
CVE-2021-31894 1 Siemens 8 Simatic Pcs 7, Simatic Pcs 7 Firmware, Simatic Pdm and 5 more 2024-11-21 8.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
CVE-2021-31893 1 Siemens 8 Simatic Pcs, Simatic Pcs Firmware, Simatic Pdm and 5 more 2024-11-21 7.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.
CVE-2021-31340 1 Siemens 50 Simatic Reader Rf610r Cmiit, Simatic Reader Rf610r Cmiit Firmware, Simatic Reader Rf610r Etsi and 47 more 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.
CVE-2021-29998 2 Siemens, Windriver 71 Ruggedcom Win Subscriber Station, Ruggedcom Win Subscriber Station Firmware, Scalance X200-4 P Irt and 68 more 2024-11-21 9.8 Critical
An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client.
CVE-2021-27395 1 Siemens 4 Simatic Process Historian 2013, Simatic Process Historian 2014, Simatic Process Historian 2019 and 1 more 2024-11-21 8.1 High
A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data.
CVE-2021-25675 1 Siemens 1 Simatic S7-plcsim 2024-11-21 5.5 Medium
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service.
CVE-2021-25674 1 Siemens 1 Simatic S7-plcsim 2024-11-21 5.5 Medium
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a NULL pointer deference condition could cause the application to terminate unexpectedly and must be restarted to restore the service.
CVE-2021-25673 1 Siemens 1 Simatic S7-plcsim 2024-11-21 5.5 Medium
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.