| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Salt before 2015.8.11 allows deleted minions to read or write to minions with the same id, related to caching. |
| Vulnerability in the MySQL Server product of Oracle MySQL (component: Server: DML). Supported versions that are affected are 8.4.0-8.4.4 and 9.0.0-9.2.0. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server. CVSS 3.1 Base Score 4.9 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H). |
| Vulnerability in the JD Edwards EnterpriseOne Tools product of Oracle JD Edwards (component: Web Runtime SEC). Supported versions that are affected are 9.2.0.0-9.2.9.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise JD Edwards EnterpriseOne Tools. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in JD Edwards EnterpriseOne Tools, attacks may significantly impact additional products (scope change). Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of JD Edwards EnterpriseOne Tools accessible data as well as unauthorized read access to a subset of JD Edwards EnterpriseOne Tools accessible data. CVSS 3.1 Base Score 5.4 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N). |
| The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings. |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. |
| A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a drive-by attack to load the firmware on any CMS8000 device. |
| The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |
| Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration. |
| mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information. |
| The Weintek cMT product line is vulnerable to various improper access controls, which may allow an unauthenticated attacker to remotely access and download sensitive information and perform administrative actions on behalf of a legitimate administrator. |
| Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-284 Improper Access Control, and stores project data in a directory with improper access control lists. |
| The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information. |
| A denial of service vulnerability exists in the Modbus configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger this vulnerability. |
| A denial of service vulnerability exists in the SeaMax remote configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger this vulnerability. |
| The firmware of InHand Networks InRouter302 V3.5.45 introduces fixes for TALOS-2022-1472 and TALOS-2022-1474. The fixes are incomplete. An attacker can still perform, respectively, a privilege escalation and an information disclosure vulnerability. |
| A vulnerability has been found in Adminer Login 1.4.4 and classified as problematic. This vulnerability affects unknown code. The manipulation leads to improper access controls. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. |
| A vulnerability classified as critical was found in SourceCodester Book Store Management System 1.0. This vulnerability affects unknown code of the file /bsms_ci/index.php. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-214588. |
| Cisco Unified Web and E-Mail Interaction Manager 9.0(2) improperly performs authorization, which allows remote authenticated users to remove default messaging-queue system folders via unspecified vectors, aka Bug ID CSCuo89046. |