| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic AES encryption key, which can be easily derived. |
| ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic WPA2-PSK, which can be easily derived. |
| A vulnerability, which was classified as problematic, has been found in elunez eladmin up to 2.7. Affected by this issue is some unknown functionality of the file eladmin-system\src\main\resources\config\application-prod.yml of the component Druid. The manipulation of the argument login-username/login-password leads to use of default credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. |
| The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session. |
| A use of hard-coded cryptographic key vulnerability in FortiSIEM version 5.2.6 may allow a remote unauthenticated attacker to obtain SSH access to the supervisor as the restricted user "tunneluser" by leveraging knowledge of the private key from another installation or a firmware image. |
| The Carlo Gavazzi
EOS-Box
stores hard-coded passwords in the PHP file of
the device. By using the hard-coded passwords, attackers can log into
the device with administrative privileges. This could allow the attacker
to have unauthorized access. |
| Dell PowerStore, version(s) 4.0.0.0, contain(s) an Use of Hard-coded Credentials vulnerability in the PowerStore image file. A low privileged attacker with remote access, with the knowledge of the hard-coded credentials, could potentially exploit this vulnerability to gain unauthorized access based on the hardcoded account's privileges. |
| An issue was discovered in Zoho ManageEngine ADSelfService Plus 5.x through build 5704. It uses fixed ciphering keys to protect information, giving the capacity for an attacker to decipher any protected data. |
| Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device. |
| Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system. |
| In the Kaden PICOFLUX AiR water meter an adversary can read the values through wireless M-Bus mode 5 with a hardcoded shared key while being adjacent to the device. |
| Sanitization Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel. |
| Book Store Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel. |
| A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device. |
| A vulnerability in motherboard console ports of line cards for Cisco ASR 1000 Series Aggregation Services Routers and Cisco cBR-8 Converged Broadband Routers could allow an unauthenticated, physical attacker to access an affected device's operating system. The vulnerability exists because an engineering console port is available on the motherboard of the affected line cards. An attacker could exploit this vulnerability by physically connecting to the console port on the line card. A successful exploit could allow the attacker to gain full access to the affected device's operating system. This vulnerability affects only Cisco ASR 1000 Series Routers that have removable line cards and Cisco cBR-8 Converged Broadband Routers, if they are running certain Cisco IOS XE 3.16 through 16.5 releases. Cisco Bug IDs: CSCvc65866, CSCve77132. |
| MEDHOST Document Management System contains hard-coded credentials that are used for Apache Solr access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with Apache Solr may be able to obtain or modify sensitive patient and financial information. The Apache Solr account name is dms. The password is hard-coded throughout the application, and is the same across all installations. Customers do not have the option to change passwords. The dms account for Apache Solr has access to all indexed patient documents. |
| MEDHOST Document Management System contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. PostgreSQL is used as the Document Management System database. The account name is dms. The password is hard-coded throughout the application, and is the same across all installations. Customers do not have the option to change passwords. The dms account for PostgreSQL has access to the database schema for Document Management System. |
| Backup archives were found to be encrypted with a static password across different installations, which suggest the same password may be used in all virtual appliance instances of Trend Micro Deep Discovery Director 1.1. |
| Axesstel MU553S MU55XS-V1.14 devices have a default password of admin for the admin account. |
| In android for MSM, Firefox OS for MSM, QRD Android, with all Android releases from CAF using the Linux kernel, while flashing FRP partition using reference FRP unlock, authentication method can be compromised for static keys. |