Export limit exceeded: 203743 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (2798 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-12337 1 Cisco 11 Emergency Responder, Finesse, Hosted Collaboration Solution and 8 more 2025-07-31 N/A
A vulnerability in the upgrade mechanism of Cisco collaboration products based on the Cisco Voice Operating System software platform could allow an unauthenticated, remote attacker to gain unauthorized, elevated access to an affected device. The vulnerability occurs when a refresh upgrade (RU) or Prime Collaboration Deployment (PCD) migration is performed on an affected device. When a refresh upgrade or PCD migration is completed successfully, an engineering flag remains enabled and could allow root access to the device with a known password. If the vulnerable device is subsequently upgraded using the standard upgrade method to an Engineering Special Release, service update, or a new major release of the affected product, this vulnerability is remediated by that action. Note: Engineering Special Releases that are installed as COP files, as opposed to the standard upgrade method, do not remediate this vulnerability. An attacker who can access an affected device over SFTP while it is in a vulnerable state could gain root access to the device. This access could allow the attacker to compromise the affected system completely. Cisco Bug IDs: CSCvg22923, CSCvg55112, CSCvg55128, CSCvg55145, CSCvg58619, CSCvg64453, CSCvg64456, CSCvg64464, CSCvg64475, CSCvg68797.
CVE-2020-3411 1 Cisco 1 Catalyst Center 2025-07-23 7.5 High
A vulnerability in Cisco DNA Center software could allow an unauthenticated remote attacker access to sensitive information on an affected system. The vulnerability is due to improper handling of authentication tokens by the affected software. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker access to sensitive device information, which includes configuration files.
CVE-2025-2572 1 Progress 1 Whatsup Gold 2025-07-17 5.6 Medium
In WhatsUp Gold versions released before 2024.0.3, a database manipulation vulnerability allows an unauthenticated attacker to modify the contents of WhatsUp.dbo.WrlsMacAddressGroup.
CVE-2025-29627 1 Keepersecurity 1 Keeperchat 2025-07-16 6.8 Medium
An issue in KeeperChat IOS Application v.5.8.8 allows a physically proximate attacker to escalate privileges via the Biometric Authentication Module
CVE-2020-9250 1 Huawei 2 Mate 20 Pro, Mate 20 Pro Firmware 2025-07-11 3.3 Low
There is an insufficient authentication vulnerability in some Huawei smart phone. An unauthenticated, local attacker can crafts software package to exploit this vulnerability. Due to insufficient verification, successful exploitation may impact the service. (Vulnerability ID: HWPSIRT-2019-12302) This vulnerability has been assigned a Common Vulnerabilities and Exposures (CVE) ID: CVE-2020-9250.
CVE-2012-4688 1 I-gen 1 Oplynx 2025-07-10 N/A
The Central application in i-GEN opLYNX before 2.01.9 allows remote attackers to bypass authentication via vectors involving the disabling of browser JavaScript support.
CVE-2012-5864 1 Sinapsitech 4 Esolar Duo Photovoltaic System Monitor, Esolar Light Photovoltaic System Monitor, Esolar Photovoltaic System Monitor and 1 more 2025-07-08 N/A
These Sinapsi devices do not check if users that visit pages within the device have properly authenticated. By directly visiting the pages within the device, attackers can gain unauthorized access with administrative privileges.
CVE-2014-0769 3 3s-software, Festo, Softmotion3d 4 Codesys Runtime System, Cecx-x-c1 Modular Master Controller, Cecx-x-m1 Modular Controller and 1 more 2025-07-02 N/A
The Festo CECX-X-C1 Modular Master Controller with CoDeSys and CECX-X-M1 Modular Controller with CoDeSys and SoftMotion do not require authentication for connections to certain TCP ports, which allows remote attackers to (1) modify the configuration via a request to the debug service on port 4000 or (2) delete log entries via a request to the log service on port 4001.
CVE-2014-0760 3 3s-software, Festo, Softmotion3d 4 Codesys Runtime System, Cecx-x-c1 Modular Master Controller, Cecx-x-m1 Modular Controller and 1 more 2025-07-02 N/A
The Festo CECX-X-C1 Modular Master Controller with CoDeSys and CECX-X-M1 Modular Controller with CoDeSys and SoftMotion provide an undocumented access method involving the FTP protocol, which could allow a remote attacker to execute arbitrary code or cause a denial of service (application crash) via unspecified vectors.
CVE-2025-5985 1 Fabian 1 School Fees Payment System 2025-06-17 7.3 High
A vulnerability was found in code-projects School Fees Payment System 1.0 and classified as critical. Affected by this issue is some unknown functionality. The manipulation leads to improper authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-25504 1 Niceforyou 2 Gefen Gf-avip-mc Firmware, Gefen Webfwc 2025-06-17 6.5 Medium
An issue in the /usr/local/bin/jncs.sh script of Gefen WebFWC (In AV over IP products) v1.85h, v1.86v, and v1.70 allows attackers with network access to connect to the device over TCP port 4444 without authentication and execute arbitrary commands with root privileges.
CVE-2025-5906 1 Code-projects 1 Laundry System 2025-06-13 7.3 High
A vulnerability classified as critical has been found in code-projects Laundry System 1.0. This affects an unknown part of the file /data/. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-23806 1 Hidglobal 4 Iclass Se Reader Configuration Cards, Iclass Se Reader Configuration Cards Firmware, Omnikey Secure Elements Reader Configuration Cards and 1 more 2025-06-13 5.3 Medium
Sensitive data can be extracted from HID iCLASS SE reader configuration cards. This could include credential and device administrator keys.
CVE-2023-42531 1 Samsung 1 Android 2025-06-12 6.2 Medium
Improper access control vulnerability in SmsController prior to SMR Nov-2023 Release1 allows local attackers to bypass restrictions on starting activities from the background.
CVE-2020-18305 1 Extremenetworks 2 Exos, Extremexos 2025-06-11 8 High
Extreme Networks EXOS before v.22.7 and before v.30.2 was discovered to contain an issue in its Web GUI which fails to restrict URL access, allowing attackers to access sensitive information or escalate privileges.
CVE-2022-39801 1 Sap 1 Access Control 2025-06-10 7.5 High
SAP GRC Access control Emergency Access Management allows an authenticated attacker to access a Firefighter session even after it is closed in Firefighter Logon Pad. This attack can be launched only within the firewall. On successful exploitation the attacker can gain access to admin session and completely compromise the application.
CVE-2020-7533 1 Schneider-electric 32 140cpu65260, 140cpu65260 Firmware, 140noc77101 and 29 more 2025-06-10 9.8 Critical
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
CVE-2020-16239 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2025-06-04 4.9 Medium
When an actor claims to have a given identity, Philips SureSigns VS4, A.07.107 and prior does not prove or insufficiently proves the claim is correct.
CVE-2020-14477 1 Philips 16 Affiniti 50, Affiniti 50 Firmware, Affiniti 70 and 13 more 2025-06-04 3.6 Low
In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information.
CVE-2020-25183 1 Medtronic 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware 2025-05-22 8 High
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.