| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the onboardee module. The issue results from improper access control. An attacker can leverage this vulnerability to execute code in the context of root. |
| When an affected
product receives a valid CIP message from an unauthorized or unintended
source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port
44818/UDP that changes the product’s configuration and network
parameters, a DoS condition can occur. This situation could cause loss
of availability and a disruption of communication with other connected
devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| StreamLabs Desktop Application 1.9.0 is vulnerable to Incorrect Access Control via obs64.exe. An attacker can execute arbitrary code via a crafted .exe file. |
| The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services. |
| Erxes <1.6.1 is vulnerable to Incorrect Access Control. An attacker can bypass authentication by providing a "User" HTTP header that contains any user, allowing them to talk to any GraphQL endpoint. |
| Adobe Commerce versions 2.4.8, 2.4.7-p5, 2.4.6-p10, 2.4.5-p12, 2.4.4-p13 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. An attacker could leverage this vulnerability to bypass security measures and gain limited write access. Exploitation of this issue does not require user interaction. |
| Improper access control in PAM feature in Devolutions Server allows a PAM user to self approve their PAM requests even if disallowed by the configured policy via specific user interface actions.
This issue affects Devolutions Server versions from 2025.1.3.0 through 2025.1.6.0, and all versions up to 2024.3.15.0. |
| Incorrect access control in xmall v1.1 allows attackers to bypass authentication via a crafted GET request to /index. |
| Philips SureSigns VS4, A.07.107 and prior
does not restrict or incorrectly restricts access to a resource from an unauthorized actor. |
| Insufficient data validation in DevTools in Google Chrome prior to 136.0.7103.59 allowed a remote attacker who convinced a user to engage in specific UI gestures to bypass discretionary access control via a crafted HTML page. (Chromium security severity: Medium) |
| The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device. |
| Medtronic MiniMed Insulin Pumps
are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery. |
| A vulnerability classified as critical has been found in westboy CicadasCMS 1.0. This affects an unknown part of the file /upload/ of the component JSP Parser. The manipulation of the argument File leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
| A vulnerability classified as critical was found in huanfenz/code-projects StudentManager 1.0. This vulnerability affects unknown code of the file /upload/uploadArticle.do of the component Announcement Management Section. The manipulation of the argument File leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical has been found in itsourcecode Content Management System 1.0. This affects an unknown part of the file /admin/add_topic.php?category=BBS. The manipulation of the argument Cover Image leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
| ZGR TPS200 NG in its 2.00 firmware version and 1.01 hardware version, does not properly accept specially constructed requests. This allows an attacker with access to the network where the affected asset is located, to operate and change several parameters without having to be registered as a user on the web that owns the device. |
| A vulnerability was found in TOTOLINK A3700R 9.1.2u.5822_B20200513 and classified as critical. Affected by this issue is the function setDdnsCfg of the file /cgi-bin/cstecgi.cgi. The manipulation leads to improper access controls. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in TOTOLINK A3700R 9.1.2u.5822_B20200513. It has been classified as critical. This affects the function setUPnPCfg of the file /cgi-bin/cstecgi.cgi. The manipulation leads to improper access controls. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in TOTOLINK A3700R 9.1.2u.5822_B20200513. It has been declared as critical. This vulnerability affects the function setScheduleCfg of the file /cgi-bin/cstecgi.cgi. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in TOTOLINK A3700R 9.1.2u.5822_B20200513. It has been rated as critical. Affected by this issue is the function setL2tpServerCfg of the file /cgi-bin/cstecgi.cgi. The manipulation leads to improper access controls. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. |