Export limit exceeded: 237703 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (14809 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-9303 | 1 Totolink | 2 A720r, A720r Firmware | 2025-10-06 | 8.8 High |
| A security flaw has been discovered in TOTOLINK A720R 4.1.5cu.630_B20250509. This issue affects the function setParentalRules of the file /cgi-bin/cstecgi.cgi. Performing manipulation of the argument desc results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be exploited. | ||||
| CVE-2014-2364 | 1 Advantech | 1 Advantech Webaccess | 2025-10-06 | N/A |
| Multiple stack-based buffer overflows in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary code via a long string in the (1) ProjectName, (2) SetParameter, (3) NodeName, (4) CCDParameter, (5) SetColor, (6) AlarmImage, (7) GetParameter, (8) GetColor, (9) ServerResponse, (10) SetBaud, or (11) IPAddress parameter to an ActiveX control in (a) webvact.ocx, (b) dvs.ocx, or (c) webdact.ocx. | ||||
| CVE-2025-30176 | 1 Siemens | 5 Simatic Pcs Neo, Sinec Nms, Sinema Remote Connect and 2 more | 2025-10-03 | 7.5 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | ||||
| CVE-2025-30174 | 1 Siemens | 4 Sinec Nms, Sinema Remote Connect, Totally Integrated Automation Portal and 1 more | 2025-10-03 | 7.5 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | ||||
| CVE-2025-55847 | 1 Wavlink | 3 M86x3a V240730, Wl-wn586x3a, Wl-wn586x3a Firmware | 2025-10-03 | 8.8 High |
| Wavlink M86X3A_V240730 contains a buffer overflow vulnerability in the /cgi-bin/ExportAllSettings.cgi file. The vulnerability arises because the Cookie parameter does not properly validate the length of input data. Attackers can exploit this to execute arbitrary code or cause a denial of service (DoS) on the system | ||||
| CVE-2025-55558 | 2 Linuxfoundation, Pytorch | 2 Pytorch, Pytorch | 2025-10-03 | 7.5 High |
| A buffer overflow occurs in pytorch v2.7.0 when a PyTorch model consists of torch.nn.Conv2d, torch.nn.functional.hardshrink, and torch.Tensor.view-torch.mv() and is compiled by Inductor, leading to a Denial of Service (DoS). | ||||
| CVE-2025-9023 | 1 Tenda | 4 Ac18, Ac18 Firmware, Ac7 and 1 more | 2025-10-03 | 8.8 High |
| A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-11091 | 1 Tenda | 2 Ac21, Ac21 Firmware | 2025-10-03 | 8.8 High |
| A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited. | ||||
| CVE-2025-11123 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 8.8 High |
| A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used. | ||||
| CVE-2025-11122 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 8.8 High |
| A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used. | ||||
| CVE-2025-11120 | 1 Tenda | 3 Ac18, Ac18 Firmware, Ac8 | 2025-10-03 | 8.8 High |
| A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited. | ||||
| CVE-2024-52065 | 1 Rti | 1 Connext Professional | 2025-10-02 | 7.1 High |
| Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in RTI Connext Professional on non-Windows (Persistence Service) allows Buffer Overflow via Environment Variables.This issue affects Connext Professional: from 7.0.0 before 7.3.0.2, from 6.1.1.2 before 6.1.2.21, from 5.3.1.40 before 5.3.1.41. | ||||
| CVE-2025-7207 | 1 Mruby | 1 Mruby | 2025-10-01 | 3.3 Low |
| A vulnerability, which was classified as problematic, was found in mruby up to 3.4.0-rc2. Affected is the function scope_new of the file mrbgems/mruby-compiler/core/codegen.c of the component nregs Handler. The manipulation leads to heap-based buffer overflow. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The name of the patch is 1fdd96104180cc0fb5d3cb086b05ab6458911bb9. It is recommended to apply a patch to fix this issue. | ||||
| CVE-2025-8402 | 1 Mattermost | 2 Mattermost, Mattermost Server | 2025-10-01 | 4.9 Medium |
| Mattermost versions 10.8.x <= 10.8.3, 10.5.x <= 10.5.8, 9.11.x <= 9.11.17, 10.10.x <= 10.10.0, 10.9.x <= 10.9.3 fail to validate import data which allows a system admin to crash the server via the bulk import feature. | ||||
| CVE-2025-29365 | 1 Spimsimulator | 1 Spim | 2025-10-01 | 9.8 Critical |
| spimsimulator spim v9.1.24 and before is vulnerable to Buffer Overflow in READ_STRING_SYSCALL. | ||||
| CVE-2025-39778 | 1 Linux | 1 Linux Kernel | 2025-10-01 | 7.1 High |
| In the Linux kernel, the following vulnerability has been resolved: objtool, nvmet: Fix out-of-bounds stack access in nvmet_ctrl_state_show() The csts_state_names[] array only has six sparse entries, but the iteration code in nvmet_ctrl_state_show() iterates seven, resulting in a potential out-of-bounds stack read. Fix that. Fixes the following warning with an UBSAN kernel: vmlinux.o: warning: objtool: .text.nvmet_ctrl_state_show: unexpected end of section | ||||
| CVE-2025-22003 | 1 Linux | 1 Linux Kernel | 2025-10-01 | 5.5 Medium |
| In the Linux kernel, the following vulnerability has been resolved: can: ucan: fix out of bound read in strscpy() source Commit 7fdaf8966aae ("can: ucan: use strscpy() to instead of strncpy()") unintentionally introduced a one byte out of bound read on strscpy()'s source argument (which is kind of ironic knowing that strscpy() is meant to be a more secure alternative :)). Let's consider below buffers: dest[len + 1]; /* will be NUL terminated */ src[len]; /* may not be NUL terminated */ When doing: strncpy(dest, src, len); dest[len] = '\0'; strncpy() will read up to len bytes from src. On the other hand: strscpy(dest, src, len + 1); will read up to len + 1 bytes from src, that is to say, an out of bound read of one byte will occur on src if it is not NUL terminated. Note that the src[len] byte is never copied, but strscpy() still needs to read it to check whether a truncation occurred or not. This exact pattern happened in ucan. The root cause is that the source is not NUL terminated. Instead of doing a copy in a local buffer, directly NUL terminate it as soon as usb_control_msg() returns. With this, the local firmware_str[] variable can be removed. On top of this do a couple refactors: - ucan_ctl_payload->raw is only used for the firmware string, so rename it to ucan_ctl_payload->fw_str and change its type from u8 to char. - ucan_device_request_in() is only used to retrieve the firmware string, so rename it to ucan_get_fw_str() and refactor it to make it directly handle all the string termination logic. | ||||
| CVE-2025-40114 | 1 Linux | 1 Linux Kernel | 2025-10-01 | 7.8 High |
| In the Linux kernel, the following vulnerability has been resolved: iio: light: Add check for array bounds in veml6075_read_int_time_ms The array contains only 5 elements, but the index calculated by veml6075_read_int_time_index can range from 0 to 7, which could lead to out-of-bounds access. The check prevents this issue. Coverity Issue CID 1574309: (#1 of 1): Out-of-bounds read (OVERRUN) overrun-local: Overrunning array veml6075_it_ms of 5 4-byte elements at element index 7 (byte offset 31) using index int_index (which evaluates to 7) This is hardening against potentially broken hardware. Good to have but not necessary to backport. | ||||
| CVE-2024-24731 | 1 Silabs | 1 Gecko Os | 2025-09-30 | 7.5 High |
| This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Silicon Labs Gecko OS. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of the http_download command. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. | ||||
| CVE-2024-23968 | 1 Chargepoint | 6 Home Flex Hardwired, Home Flex Hardwired Firmware, Home Flex Nema 14-50 Plug and 3 more | 2025-09-30 | 8.8 High |
| This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the SrvrToSmSetAutoChnlListMsg function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. | ||||