| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A stack overflow in the FTP service of Audi UTR 2.0 Universal Traffic Recorder 2.0 allows attackers to cause a Denial of Service (DoS) via a crafted input. |
| A vulnerability was found in markparticle WebServer up to 1.0. It has been declared as critical. Affected by this vulnerability is the function Buffer::HasWritten of the file code/buffer/buffer.cpp. The manipulation of the argument writePos_ leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. |
| In rare scenarios, the cpca process on the Security Management Server / Domain Management Server may exit unexpectedly, creating a core dump file. When the cpca process is down, VPN and SIC connectivity issues may occur if the CRL is not present in the Security Gateway's CRL cache. |
| A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution. |
| HCL Connections contains a broken access control vulnerability that may allow unauthorized user to update data in certain scenarios. |
| HCL BigFix Web Reports might be subject to a Denial of Service (DoS) attack, due to a potentially weak validation of an API parameter. |
| In Gatling Enterprise versions below 1.25.0, a user logging-out can still use his session token to continue using the application without expiration, due to incorrect session management. |
| libvips is a demand-driven, horizontally threaded image processing library. The heifsave operation could incorrectly determine the presence of an alpha channel in an input when it was not possible to determine the colour interpretation, known internally within libvips as "multiband". There aren't many ways to create a "multiband" input, but it is possible with a well-crafted TIFF image. If a "multiband" TIFF input image had 4 channels and HEIF-based output was requested, this led to libvips creating a 3 channel HEIF image without an alpha channel but then attempting to write 4 channels of data. This caused a heap buffer overflow, which could crash the process. This vulnerability is fixed in 8.16.1. |
| A security vulnerability has been detected in D-Link DIR-513 A1FW110. Affected is an unknown function of the file /goform/formWPS. Such manipulation of the argument webpage leads to buffer overflow. The attack may be performed from remote. The exploit has been disclosed publicly and may be used. This vulnerability only affects products that are no longer supported by the maintainer. |
| Free5gc 4.0.1 is vulnerable to Buffer Overflow. The AMF incorrectly validates the 5GS mobile identity, resulting in slice reference overflow. |
| A heap-buffer-overflow vulnerability exists in the tcpliveplay utility of the tcpreplay-4.5.1. When a crafted pcap file is processed, the program incorrectly handles memory in the checksum calculation logic at do_checksum_math_liveplay in tcpliveplay.c, leading to a possible denial of service. |
| Squid through 7.1 mishandles ASN.1 encoding of long SNMP OIDs. This occurs in asn_build_objid in lib/snmplib/asn1.c. |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the mac parameter in the fromAdvSetMacMtuWan function. |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanSpeed parameter in the fromAdvSetMacMtuWan function. |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanMTU parameter in the fromAdvSetMacMtuWan function. |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the cloneType parameter in the fromAdvSetMacMtuWan function. |
| A security flaw has been discovered in TOTOLINK A720R 4.1.5cu.630_B20250509. This issue affects the function setParentalRules of the file /cgi-bin/cstecgi.cgi. Performing manipulation of the argument desc results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be exploited. |
| Multiple stack-based buffer overflows in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary code via a long string in the (1) ProjectName, (2) SetParameter, (3) NodeName, (4) CCDParameter, (5) SetColor, (6) AlarmImage, (7) GetParameter, (8) GetColor, (9) ServerResponse, (10) SetBaud, or (11) IPAddress parameter to an ActiveX control in (a) webvact.ocx, (b) dvs.ocx, or (c) webdact.ocx. |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. |