| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the setSmartPowerManagement function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedStartTime parameter in the setSchedWifi function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedEndTime parameter in the setSchedWifi function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the firewallEn parameter in the formSetFirewallCfg function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the endIp parameter in the formSetPPTPServer function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceMac parameter in the addWifiMacFilter function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the fromSetSysTime function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the form_fast_setting_wifi_set function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the page parameter in the fromNatStaticSetting function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the startIp parameter in the formSetPPTPServer function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the formSetVirtualSer function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeed parameter in the formSetClientState function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeedUp parameter in the formSetClientState function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the formSetClientState function. |
| Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the addWifiMacFilter function. |
| Tenda AC6V1.0 V15.03.05.19 is vulnerable to Buffer Overflow via formSetMacFilterCfg. |
| A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges. |