| The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request. |
| Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant traffic. |
| CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. |
| NETGEAR Multiple Routers httpd Missing Authentication for Critical Function Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of multiple NETGEAR routers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the httpd service, which listens on TCP port 80 by default. The issue results from the lack of authentication prior to allowing access to system configuration information. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-13708. |
| A vulnerability in the management API of Cisco Catalyst Center, formerly Cisco DNA Center, could allow an unauthenticated, remote attacker to read and modify the outgoing proxy configuration settings.
This vulnerability is due to the lack of authentication in an API endpoint. An attacker could exploit this vulnerability by sending a request to the affected API of a Catalyst Center device. A successful exploit could allow the attacker to view or modify the outgoing proxy configuration, which could disrupt internet traffic from Cisco Catalyst Center or may allow the attacker to intercept outbound internet traffic. |
| CyberData
011209
Intercom exposes features that could allow an unauthenticated to gain
access and cause a denial-of-service condition or system disruption. |
| A vulnerability classified as critical has been found in code-projects Laundry System 1.0. This affects an unknown part of the file /data/. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
| The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device. |
| Missing Authentication for Critical Function in GitHub repository ikus060/rdiffweb prior to 2.5.0a6. |
| Asus RT-N12E 2.0.0.39 is affected by an incorrect access control vulnerability. Through system.asp / start_apply.htm, an attacker can change the administrator password without any authentication. |
| ZKTeco BioTime 8.5.4 is missing authentication on folders containing employee photos, allowing an attacker to view them through filename enumeration. |
| Multiple W&T products of the ComServer Series are prone to an authentication bypass. An unathenticated remote attacker, can log in without knowledge of the password by crafting a modified HTTP GET Request. |
| The memory management module has the logic bypass vulnerability. Successful exploitation of this vulnerability may affect data confidentiality. |
| authentik is an open-source identity provider. Versions prior to 2022.11.2 and 2022.10.2 are vulnerable to unauthorized user creation and potential account takeover. With the default flows, unauthenticated users can create new accounts in authentik. If a flow exists that allows for email-verified password recovery, this can be used to overwrite the email address of admin accounts and take over their accounts. authentik 2022.11.2 and 2022.10.2 fix this issue. As a workaround, a policy can be created and bound to the `default-user-settings-flow flow` with the contents `return request.user.is_authenticated`. |
| The Tatsu WordPress plugin before 3.3.12 add_custom_font action can be used without prior authentication to upload a rogue zip file which is uncompressed under the WordPress's upload directory. By adding a PHP shell with a filename starting with a dot ".", this can bypass extension control implemented in the plugin. Moreover, there is a race condition in the zip extraction process which makes the shell file live long enough on the filesystem to be callable by an attacker. |
| Two four letter word commands "wchp/wchc" are CPU intensive and could cause spike of CPU utilization on Apache ZooKeeper server if abused, which leads to the server unable to serve legitimate client requests. Apache ZooKeeper thru version 3.4.9 and 3.5.2 suffer from this issue, fixed in 3.4.10, 3.5.3, and later. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. |
| An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access. |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. |
| Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55 leads to new attack vectors. |