CVE-2020-8287 6 Debian, Fedoraproject, Nodejs and 3 more 7 Debian Linux, Fedora, Node.js and 4 more 2025-04-30 6.5 Medium
Node.js versions before 10.23.1, 12.20.1, 14.15.4, 15.5.1 allow two copies of a header field in an HTTP request (for example, two Transfer-Encoding header fields). In this case, Node.js identifies the first header field and ignores the second. This can lead to HTTP Request Smuggling.
CVE-2020-8265 6 Debian, Fedoraproject, Nodejs and 3 more 7 Debian Linux, Fedora, Node.js and 4 more 2025-04-30 8.1 High
Node.js versions before 10.23.1, 12.20.1, 14.15.4, 15.5.1 are vulnerable to a use-after-free bug in its TLS implementation. When writing to a TLS enabled socket, node::StreamBase::Write calls node::TLSWrap::DoWrite with a freshly allocated WriteWrap object as first argument. If the DoWrite method does not return an error, this object is passed back to the caller as part of a StreamWriteResult structure. This may be exploited to corrupt memory leading to a Denial of Service or potentially other exploits.
CVE-2021-27391 1 Siemens 16 Apogee Mbc \(ppc\) \(p2 Ethernet\), Apogee Mbc \(ppc\) \(p2 Ethernet\) Firmware, Apogee Mec \(ppc\) \(p2 Ethernet\) and 13 more 2025-04-23 9.8 Critical
A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges.
CVE-2022-43724 1 Siemens 1 Sicam Pas\/pqs 2025-04-22 9.8 Critical
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.
CVE-2022-43723 1 Siemens 1 Sicam Pas\/pqs 2025-04-22 7.5 High
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0), SICAM PAS/PQS (All versions >= 7.0 < V8.06). Affected software does not properly validate the input for a certain parameter in the s7ontcp.dll. This could allow an unauthenticated remote attacker to send messages and create a denial of service condition as the application crashes. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.
CVE-2022-43722 1 Siemens 1 Sicam Pas\/pqs 2025-04-22 7.8 High
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0). Affected software does not properly secure a folder containing library files. This could allow an attacker to place a custom malicious DLL in this folder which is then run with SYSTEM rights when a service is started that requires this DLL. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.
CVE-2022-30694 1 Siemens 223 6ag1151-8ab01-7ab0, 6ag1151-8ab01-7ab0 Firmware, 6ag1151-8fb01-2ab0 and 220 more 2025-04-21 6.5 Medium
The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
CVE-2022-39136 1 Siemens 2 Jt2go, Teamcenter Visualization 2025-04-21 7.8 High
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V13.3 (All versions >= V13.3.0.7 < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected application is vulnerable to fixed-length heap-based buffer while parsing specially crafted TIF files. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2022-39157 1 Siemens 1 Parasolid 2025-04-21 7.8 High
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)
CVE-2022-41660 1 Siemens 2 Jt2go, Teamcenter Visualization 2025-04-21 7.8 High
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected products contain an out of bounds write vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.
CVE-2022-41661 1 Siemens 2 Jt2go, Teamcenter Visualization 2025-04-21 7.8 High
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.
CVE-2022-41662 1 Siemens 2 Jt2go, Teamcenter Visualization 2025-04-21 7.8 High
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.
CVE-2022-41663 1 Siemens 2 Jt2go, Teamcenter Visualization 2025-04-21 7.8 High
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2022-41664 1 Siemens 2 Jt2go, Teamcenter Visualization 2025-04-21 7.8 High
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
CVE-2022-43397 1 Siemens 1 Parasolid 2025-04-21 7.8 High
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)
CVE-2022-43958 1 Siemens 1 Qms Automotive 2025-04-21 7.6 High
A vulnerability has been identified in QMS Automotive (All versions < V12.39), QMS Automotive (All versions < V12.39). User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.
CVE-2017-9945 1 Siemens 2 7km Pac Switched Ethernet Profinet Expansion Module, 7km Pac Switched Ethernet Profinet Expansion Module Firmware 2025-04-20 N/A
In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover.
CVE-2017-9944 1 Siemens 2 7kt Pac1200 Data Manager, 7kt Pac1200 Data Manager Firmware 2025-04-20 N/A
A vulnerability has been identified in Siemens 7KT PAC1200 data manager (7KT1260) in all versions < V2.03. The integrated web server (port 80/tcp) of the affected devices could allow an unauthenticated remote attacker to perform administrative operations over the network.
CVE-2017-9942 1 Siemens 1 Sipass Integrated 2025-04-20 N/A
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain credentials from the systems.
CVE-2017-9941 1 Siemens 1 Sipass Integrated 2025-04-20 N/A
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.