| ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. |
| Improper length handling when parsing multiple cookie fields (including TRACKID) allows an unauthenticated remote attacker to send oversized cookie values and trigger a stack buffer overflow, resulting in a denial‑of‑service condition and possible remote code execution. |
| An unauthenticated remote attacker can bypass authentication by exploiting insufficient URI validation and using path traversal sequences (e.g., /js/../cgi-bin/post.cgi), gaining unauthorized access to protected CGI endpoints and configuration downloads. |
| User credentials are stored using AES‑ECB encryption with a hardcoded key. An unauthenticated remote attacker obtaining the configuration file can decrypt and recover plaintext usernames and passwords, especially when combined with the authentication bypass. |
| An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device. |
| An authenticated remote attacker with high privileges can exploit the OpenVPN configuration via the web-based management interface of a WAGO PLC. If user-defined scripts are permitted, OpenVPN may allow the execution of arbitrary shell commands enabling the attacker to run arbitrary commands on the device. |
| eap.c in pppd in ppp 2.4.2 through 2.4.8 has an rhostname buffer overflow in the eap_request and eap_response functions. |
| CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command. |
| CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow. |
| CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow. |
| CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. |
| CODESYS V2 Web-Server before 1.1.9.20 has a a Buffer Copy without Checking the Size of the Input. |
| CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check. |
| CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write. |
| CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Read. |
| CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation. |
| Crafted web server requests may cause a heap-based buffer overflow and could therefore trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22. |
| Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22. |
| In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests can trigger a parser error. Since the parser result is not checked under all conditions, a pointer dereference with an invalid address can occur. This leads to a denial of service situation. |
| In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests may cause a Null pointer dereference in the CODESYS web server and may result in a denial-of-service condition. |