Search Results (96 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-36872 2 Bacnet Test, Philips 2 Test Server, Interoperability Solution Xds 2026-07-28 N/A
BACnet Test Server versions up to and including 1.01 contains a remote denial of service vulnerability in its BACnet/IP BVLC packet handling. The server fails to properly validate the BVLC Length field in incoming UDP BVLC frames on the default BACnet port (47808/udp). A remote unauthenticated attacker can send a malformed BVLC Length value to trigger an access violation and crash the application, resulting in a denial of service.
CVE-2017-0199 2 Microsoft, Philips 6 Office, Windows 7, Windows Server 2008 and 3 more 2026-04-22 7.8 High
Microsoft Office 2007 SP3, Microsoft Office 2010 SP2, Microsoft Office 2013 SP1, Microsoft Office 2016, Microsoft Windows Vista SP2, Windows Server 2008 SP2, Windows 7 SP1, Windows 8.1 allow remote attackers to execute arbitrary code via a crafted document, aka "Microsoft Office/WordPad Remote Code Execution Vulnerability w/Windows API."
CVE-2017-0143 3 Microsoft, Philips, Siemens 28 Server Message Block, Windows 10 1507, Windows 10 1511 and 25 more 2026-04-22 8.8 High
The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0144, CVE-2017-0145, CVE-2017-0146, and CVE-2017-0148.
CVE-2021-26262 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2026-04-02 5.5 Medium
Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CVE-2021-26248 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2026-04-02 5.5 Medium
Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CVE-2020-16228 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2026-02-23 6.4 Medium
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
CVE-2020-16224 1 Philips 1 Patient Information Center Ix 2026-02-23 6.5 Medium
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart.
CVE-2020-16222 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2026-02-23 8.8 High
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16220 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2026-02-23 4.3 Medium
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.
CVE-2020-16218 1 Philips 1 Patient Information Center Ix 2026-02-23 3.5 Low
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
CVE-2020-16216 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2026-02-23 6.5 Medium
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
CVE-2020-16214 1 Philips 1 Patient Information Center Ix 2026-02-23 5.0 Medium
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.
CVE-2020-16247 1 Philips 1 Clinical Collaboration Platform 2025-06-04 6.8 Medium
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
CVE-2020-16241 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2025-06-04 6.3 Medium
Philips SureSigns VS4, A.07.107 and prior does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CVE-2020-16239 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2025-06-04 4.9 Medium
When an actor claims to have a given identity, Philips SureSigns VS4, A.07.107 and prior does not prove or insufficiently proves the claim is correct.
CVE-2020-16237 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2025-06-04 2.1 Low
Philips SureSigns VS4, A.07.107 and prior receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2020-16200 1 Philips 1 Clinical Collaboration Platform 2025-06-04 6.5 Medium
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.
CVE-2020-16198 1 Philips 1 Clinical Collaboration Platform 2025-06-04 5 Medium
When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct.
CVE-2020-14525 1 Philips 1 Clinical Collaboration Platform 2025-06-04 3.5 Low
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
CVE-2020-14518 1 Philips 1 Dreammapper 2025-06-04 5.3 Medium
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.