| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Crestron DMC-STRO 1.0 devices allow remote command execution as root via shell metacharacters to the ping function. |
| The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root. |
| Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 rely on the client to perform authentication, which allows remote attackers to obtain access by setting the value of objresp.authenabled to 1. |
| Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 allow remote attackers to bypass authentication via a direct request to a page other than index.html. |
| Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 allow remote attackers to bypass authentication and change settings via a JSON API call. |
| Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 use a hardcoded 0xb9eed4d955a59eb3 X.509 certificate from an OpenSSL Test Certification Authority, which makes it easier for remote attackers to conduct man-in-the-middle attacks against HTTPS sessions by leveraging the certificate's trust relationship. |
| Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 have a hardcoded password of admin for the admin account, which makes it easier for remote attackers to obtain access via the web management interface. |
| Multiple cross-site request forgery (CSRF) vulnerabilities on Crestron Electronics DM-TXRX-100-STR devices with firmware through 1.3039.00040 allow remote attackers to hijack the authentication of arbitrary users. |
| Directory traversal vulnerability in cgi-bin/login.cgi on Crestron AirMedia AM-100 devices with firmware before 1.4.0.13 allows remote attackers to read arbitrary files via a .. (dot dot) in the src parameter. |
| Directory traversal vulnerability in cgi-bin/rftest.cgi on Crestron AirMedia AM-100 devices with firmware before 1.4.0.13 allows remote attackers to execute arbitrary commands via a .. (dot dot) in the ATE_COMMAND parameter. |
| On Crestron DM-NVX-DIR, DM-NVX-DIR80, and DM-NVX-ENT devices before the DM-XIO/1-0-3-802 patch, the password can be changed by sending an unauthenticated WebSocket request. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a "stopped" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge. |
| Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root. |